R Floorzz Floor heating plates

RFloorzz_floor_heating_plates

R Floorzz underfloor heating plates are prefabricated dry construction floor systems for underfloor heating. R Floorzz underfloor heating plates are specially developed for efficient processing of underfloor heating in renovation, transformation and prefab construction. R Floorzz underfloor heating plates are strong, pressure resistant, fire resistant and heat accumulating.

Because of the different patterns and possibility for different pipe thicknesses, there is a solution for every type of installation. R Floorzz is suitable for all pipe thickness underfloor heating and is suitable for Low Temperature Heating (LTV) installations.

Because of our own office and production in the Netherlands, we are flexible and happy to think along with you about your needs. It is also possible to provide customization for your specific project or integration into your own systems.

The advantages of R Floorzz floor heating plates

R Floorzz underfloor heating boards are unique and specially developed for efficient installation of underfloor heating in renovation, prefab, chalet and transformation construction. What are the advantages of the R Floorzz underfloor heating dry construction system:

  • Suitable for all subfloors;
  • Ideal for underfloor heating on structural floors other than standard;
  • Supplied ready-to-use including heating pipes and Pouring compound;
  • Choose to assemble it yourself or have it assembled by our mechanics;
  • Assembly possible throughout the Netherlands;
  • Low structure;
  • Quick to assemble;
  • Safe and energy efficient.

R Floorzz underfloor heating is applicable to any surface. When assembling R Floorzz underfloor heating panels, the minimum amount of milling work and the shortest possible drying time is taken into account. This makes it possible to fit a house with complete underfloor heating in one day.

All R Floorzz products are produced in the Netherlands. The floor elements are made in our own factory in Barneveld. R Floorzz floor heating plates are available in two different designs:

  • Mono floor heating slabs;
  • Duo / estrich floor heating slabs.

The mono floor elements consist of one homogeneous slab and the duo floor elements consist of two slabs. Where necessary with the addition of a sheet of wood fiber or mineral wool. These estrich floor heating boards are also available as impact sound reducing insulated floor boards.

For a more detailed explanation of the Mono and Duo floor elements, take a look below at what differentiates these two different elements from each other and the different areas of application.

Mono floor heating plates

R Floorzz Mono floor heating plates are prefabricated dry construction floor systems for underfloor heating. The R Floorzz Mono floor element consists of one R Floorzz sheet with fire class A1. R Floorzz underfloor heating plates are specially developed for efficient processing of underfloor heating in renovation, transformation and prefab construction.

R Floorzz Mono floor elements are strong, pressure resistant, fire resistant and heat accumulating. Because of the different milling patterns and possibility for different pipe thicknesses, there is a solution for every type of installation. R Floorzz is suitable for all pipe thicknesses up to 16 mm pipe. This makes R Floorzz very suitable for Low Temperature Heating installations.

Application
The R Floorzz Mono floor heating boards are used on wood where the floor element can be attached to the substructure in, for example, chalets, homes with renovation floors and timber frame buildings.

Request a quote
Floor heating from our own factory

Duo / estrich floor heating plates

R Floorzz Duo floor heating boards are specially designed for upgrading old floors in renovation and transformation construction. In addition, they are very suitable for installing underfloor heating and is laid as a floating subfloor.

The Duo floor element is specifically suitable for renovation of old floors or floors where low weight, low build-up height and pressure resistance play an important role.

The R Floorzz Duo floor heating board consists of two R Floorzz boards with a fire class A1. They are factory glued together with a lip weld of 50 mm. The R Floorzz Duo floor element can, if desired, be factory fitted with (various types of) insulation material on the underside for additional floor requirements. Think for example of good contact sound insulating, fire resistant or thermal properties. We can manufacture insulated floor plates for your project.

Application
Estrich Duo floor heating boards from R Floorzz are used in buildings with various subfloors where there is a noise issue and a fire requirement of 60 minutes (EI) is required.

In addition, Estrich Duo floor elements are ideally suited for use on levelling granules. These are used, for example, for uneven floors or sloping floors.

Request a quote
Floor heating Arnhem
Adjusting Underfloor Heating
Floor heating costs
Setting floor heating

Hallmarks

R Floorzz floor heating plates are made of a specially developed plate material used exclusively for and by R Floorzz. Both the milled plate and the cover plate are made of the same exclusive material.

This material has several properties that are ideally suited for a high-quality floor element. Our exclusive material:

  • Is impact resistant;
  • Can withstand a splash of water;
  • Has high point load and compressive strength;
  • Has good conduction, distribution and accumulation of energy;
  • Is of low weight compared to plaster.

R Floorzz floor heating boards are easy to saw, staple and screw. Loose boards with a thickness smaller than 12 mm can even be cut to size with a Stanley knife.

R Floorzz floorboards have excellent properties for heating and cooling your floor.

In addition, R Floorzz floor elements have the following labels:

FIRE RESISTANCE

R Floorzz floor heating boards are widely applicable and have good fire-resistant properties.

R Floorzz floor heating boards have been tested at Efectis and are non-combustible according to fire class A1 (NEN 13501-1). The assembled R Floorzz floor system (including pipe) with casting compound or cover plate is 60 minutes fire resistant, which means you meet the most stringent standards.

The fire resistance of R Floorzz is assessed from top to bottom. This method is especially requested in apartments and other construction projects such as wood frame. With this, you assemble a solid but above all safe system with the R Floorzz floor system.

You do not need to make any additional adjustments to increase fire resistance from top to bottom, just apply R Floorzz as it is intended.

NOISE REDUCTION

We are regularly asked if we have as good a product as plaster bonded products. The answer to this is clear: "Yes, we do.

The R Floorzz Estrich Duo underfloor heating boards with wood fiber board have a sound reduction of 10 dB impact sound and 4 dB airborne sound. This makes the sound resistance of R Floorzz Estrich Duo floor elements better than many other solutions with gypsum in combination with underfloor heating.

With R Floorzz Estrich Duo floor elements, it is not necessary to modify the ceiling system for impact sound reduction unlike many other solutions.

To reduce airborne noise, it is important to seal the floor properly. You can do this with our R Floorzz floor heating boards. We advise you to make more provisions in your home or work environment to reduce airborne noise.

HEAT ACCUMULATION

The R Floorzz Estrich Duo floor heating boards have a high energy storage capacity. As a result, the floor has high comfort when it comes to heat dispersion. Heat accumulation means "storing energy in a medium. The goal is to release this energy at a later time. The main purpose of heat accumulation is to contribute to an energy-efficient building.

So heat accumulation is a process. A process of storing and releasing energy. The R Floorzz Estrich Duo floor heating boards have a great accumulating capacity compared to gypsum-like board materials. This ability is altogether great compared to synthetic materials such as EPS and XPS and the associated heat-conducting metal wing slats. The latter materials, while having high conductivity, have almost no accumulating capacity.

The heat capacity of the R Floorzz Duo floor elements is 1501 kJ/m3∙K. The storage and release capacity of energy of the R Floorzz Duo floor elements is thus 10 to 15% higher than other materials available for the same area of application in floor and wall heating in dry construction underfloor heating. A higher storage capacity and thus a higher capacity to release energy evenly where it is intended, gives significantly more comfort in your living, living or working environment.

PRESS

The R Floorzz Estrich Duo underfloor heating boards have a high compressive strength. Compared to other subfloor materials such as gypsum fiber boards or synthetic materials such as EPS or XPS, the R Floorzz values in compressive strength are much higher and therefore higher quality for your floor.

In comparison, gypsum bonded floorboards have an average surface hardness of between 13 and 15 mm. R Floorzz Estrich Duo floor heating boards have a surface hardness of 6 - 6.5 mm according to NEN 520. The Brinell hardness of the R Floorzz material is 48N/mm2. For gypsum fiberboard this is 30N/mm2.

As a result, R Floorzz Estrich Duo underfloor heating boards are almost twice as strong compared to other materials. An important and valuable property for a floor that is lived on and/or worked on daily.

Request a quote

Processing benefits in brief

  • Dry build system, less waiting time
  • Great for renovation, prefab and transformation projects
  • Suitable for wooden floors on first floor but also upper floors
  • Less milling on the construction site
  • Less dust in the workplace
  • Low mounting height
  • Suitable for 14 mm and 16 mm underfloor heating pipe
  • Larger heating groups, fewer manifolds

Dry build system, less waiting time

R Floorzz floor elements are laid directly on the subfloor and can be covered with the R Floorzz cover plate. By using the cover plate, you can start laying your decorative floor immediately.

Your decorative flooring supplier should always inspect the floor with their own expertise before the decorative flooring is processed.

Great for renovation, prefab and transformation projects

R Floorzz floor elements are prefabricated dry construction floor systems for underfloor heating. The R Floorzz floor elements are specially developed for efficient installation of underfloor heating in renovation, transformation and prefab construction.

Suitable for wooden floors on first floor but also upper floors

R Floorzz floor elements are prefabricated dry construction floor systems for underfloor heating. With R Floorzz mono and duo floor elements, you can start installing underfloor heating right away. You no longer need to cut into these boards or work your subfloor to install underfloor heating.

Less milling on the construction site

Because of the different patterns and possibility for different pipe thicknesses, there is a solution for every type of installation. R Floorzz floor elements are delivered in different patterns, allowing you to install your floor heating with an installation plan without fear. R Floorzz is suitable for pipe thicknesses up to 16 mm.

Less dust in the workplace

Because R Floorzz is milled in the factory and delivered to the construction site with different patterns, there is virtually no need for milling. It is only necessary to lay the R Floorzz in trailing bond, requiring you to cut a number of boards.

Low mounting height

R Floorzz has a build-up height starting at 31 mm. This build-up height is low compared to suppliers of underfloor heating elements.

Suitable for 14 mm and 16 mm underfloor heating pipe

Due to the different patterns and possibility for different pipe thicknesses, there is a solution for every type of installation. R Floorzz is suitable for up to 16 mm. pipe thicknesses. This makes R Floorzz very suitable for Low Temperature Heating (LTV) installations.

Larger heating groups, fewer manifolds

R Floorzz is suitable up to pipe thickness 16 mm. By using larger diameter pipes you will need fewer groups and may be larger than using diameter 12 mm. pipes, for example.

Advantage product features in brief

  • Up to 15% higher energy uptake and release
  • Double surface hardness in accordance with EN 520
  • Fire class A1 in accordance with EN13501-1
  • Up to 60 minutes of fire resistance
  • Up to 10dB contact sound insulation solutions
  • Suitable for Low Temperature Heating Systems

Up to 15% higher energy uptake and release

The heat output of R Floorzz floor elements have excellent heat output due to their unique properties and are very suitable for Low Temperature Heating (LTV). The heat output is often indicated per m². The output of the various R Floorzz systems is approximately between 86 and 160 watts per m². The final output depends on your installation and insulation of your home or building.

Double surface hardness in accordance with EN 520

The R Floorzz floor elements have a high compressive strength. Compared to other subfloor materials such as gypsum fiber boards or synthetic materials such as EPS or XPS, the R Floorzz values in compressive strength are much higher and therefore higher quality for your floor. In comparison, gypsum bonded boards or elements have an average surface hardness of between 13 and 15mm. R Floorzz floor elements have a surface hardness of 6 - 6.5mm according to EN 520. The Brinell hardness of the R Floorzz material is 48N/mm², with gypsum fiberboard it is only 30N/mm². This makes R Floorzz floor elements almost twice as strong as other materials. An important property for a floor on which people live and/or work every day.

Fire class A1 in accordance with EN13501-1

R Floorzz floor elements are non-combustible and therefore have fire class A1 according to EN 13501-1.

Up to 60 minutes of fire resistance

For special requirements such as fire resistance or sound insulation, other strict regulations often apply to building the overall construction. R Floorzz Floor elements are rated for fire resistance from top to bottom up to 60 minutes.

Up to 10dB contact sound insulation solutions

R Floorzz duo floor elements in combination with wood fiber board have airborne sound insulation up to 15 dB and impact sound insulation up to 10 dB. These values are in accordance with the current building code.

Suitable for Low Temperature Heating Systems

R Floorzz is a pre-milled board that is only suitable for 'low temperature floor heating systems'. The temperature of the slab should never exceed 40 degrees Celsius.

Top 10 most frequently asked questions

How much noise reduction do I achieve with the R Floorzz duo floor system?

Where can I install this floor system?

Can I work with any pipe thickness?

Can R Floorzz help me install the flooring system?

What is the surface hardness of R Floorzz flooring systems?

How much accumulating power does R Floorzz have?

Where can I buy R Floorzz?

Can I use R Floorzz in a bathroom?

Start cost calculation Start quotation request Make an appointment Call 0342 760 200 Send an email